Passed on the latest inspection dated April 8, 2025.
3750 18TH ST · Castro/Upper Market
Latest inspection: 0 red flags; 16 recorded across this inspection history.
Inspection History
April 8, 2025 — Passed
0 red flags recorded · 45 minutes on site.
No violations recorded on this inspection.
March 20, 2025 — Passed
15 red flags recorded · 120 minutes on site.
The floor finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms. (Code 114268)
Provide a 3-compartment sink with two integral metal drainboards for manually washing, rinsing, and sanitizing equipment and utensils. (Code 114099)
Lightbulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is nonprepackaged ready-to-eat food, clean equipment, utensils, and linens, or unwrapped single-use articles. (Code 114252.1)
Floor-mounted equipment that is not easily movable shall be sealed to the floor. (Code 114130, 114169)
Floor surfaces shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius coving and shall extend up the wall at least 4 inches. (Code 114268)
Equipment that discharges liquid waste, e.g. food preparation sinks, dishwashing machines, steam tables, ice machines and bins, espresso machines, walk-in refrigeration units, shall have approved indirect drainage through an air gap into a floor sink or other approved receiving vessel. (Code 114193, 114193.1, 114269)
Floor surfaces shall be sloped 1:50 to the floor drains. (Code 114193, 114193.1, 114269)
An air gap between the water supply inlet and the flood level rim of the plumbing fixture shall be at least twice the diameter of the water supply inlet and may not be less than 1 inch. (Code 114193, 114193.1, 114269)
Provide a floor plan showing the path-of-travel to the refuse storage area. (Code 114244, 114245)
Lockers or other suitable facilities shall be located in a designated room or area where contamination of food, equipment, utensils, linens, and single-use articles cannot occur. (Code 114256)
All equipment shall be installed on castors, six (6) inch high round metal legs, or on a minimum four (4) inch high curb or pedestal with a continuously coved base at the juncture. (Code 114130, 114169)
Wall and ceiling finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms. (Code 114271)
At least one curbed cleaning facility or janitorial sink equipped with hot and cold water and a drain shall be provided and conveniently located. (Code 114279, 114281, 114282)
A food facility shall at all times be constructed, equipped, and maintained, and operated as to prevent the entrance and harborage of animals, birds, and vermin, including, but not limited to rodents and insects. (Code 114266, 114257, 114257.1, 114259)
Conduits of all types shall be installed within walls as practicable. When otherwise installed, they shall be mounted or enclosed so as to facilitate cleaning. (Code 114271(d))
October 15, 2024 — Passed
1 red flag recorded · 20 minutes on site.
Eliminate the infestation/activity of cockroaches/rodents/flies/vermin from the food facility by using only approved methods. Remove all evidence of the infestation and thoroughly clean and sanitize all affected surfaces. Construct, equip, maintain and operate the food facility so as to prevent the entrance and harborage of animals, birds and vermin including, but not limited to, rodents and insects. (Code 114259, 114259.1, 114259.4, 114259.5)
October 8, 2024 — Passed
0 red flags recorded · 30 minutes on site.
No violations recorded on this inspection.
February 20, 2024 — Passed
0 red flags recorded · 30 minutes on site.
No violations recorded on this inspection.
About this data: San Francisco Department of Public Health inspection records published through DataSF. Findings are snapshots from inspection dates and may have been corrected since. View the official city records.