April 7, 2025 — Passed
9 red flags recorded · 120 minutes on site.
- Equipment that discharges liquid waste, e.g. food preparation sinks, dishwashing machines, steam tables, ice machines and bins, espresso machines, walk-in refrigeration units, shall have approved indirect drainage through an air gap into a floor sink or other approved receiving vessel.
- Wall and ceiling finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms.
- Floor surfaces shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius coving and shall extend up the wall at least 4 inches.
- Hand sinks shall be sufficient in number and conveniently located so as to be accessible at all times.
- Food on display shall be protected from contamination by approved a sneeze guard (e.g. vertical glass sneezeguard 60" Above Finished Floor).
- The floor finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms.
- All equipment shall be installed on castors, six (6) inch high round metal legs, or on a minimum four (4) inch high curb or pedestal with a continuously coved base at the juncture.
- The water supply shall be from a water system approved by the local enforcement agency.
- All new and used equipment and utensils shall be certified or classified for sanitation by an American National Standards Institute (ANSI) accredited certification program, e.g. NSF, ETL Sanitation, UL Sanitation, CSA Sanitation.